The modular office buildings are built off-site in sections and then delivered to your site for installation. The off-site construction process helps you get your commercial modular building established fast, with less mess and disruption.
Sometimes changes in your business location create new demands for in-plant office space utilization. CID's modular offices and buildings provide you with the flexibility to respond to your modular office needs. These modular office buildings can be used for a variety of industries, such as:
These modular offices house internal meetings, current or potential clients, and many other office events. CID can customize modular buildings to fit your company's exact needs and provide an outstanding modular office building manufacturer for various applications. Contact us today to discuss your unique application or need.
Outdoor Modular Mobile Office
Space is potential. Potential for profit. CID gives you the power to adapt that potential to meet virtually any requirement. From outdoor modular mobile offices to control pulpits, CID products create the functional space configuration that's ideal for your application in the form of custom-designed steel structures that readily integrate with existing utility connections, ventilation, and fixtures.
States We Work In:
Alabama, Arkansas, California, Canada Colorado, Connecticut, Delaware, Florida, Georgia, Idaho, Illinois, Indiana, Iowa, Kentucky, Louisiana, Maine, Maryland, Massachusetts, Mexico, Michigan, Mississippi, Missouri, New Hampshire, New Jersey, New York, North Carolina, North Dakota, Ohio, Pennsylvania, Rhode Island, South Carolina, South Dakota, Tennessee, Texas, Vermont, Virginia, West Virginia, Wisconsin.
Specifications
•PHASE #1: Basic Structure - Single Module Overall Outside Dimension
•PHASE #2: Load Bearing Roof Deck
•PHASE #3: Floor Framing, Finished Floor, Doors, Frames & Acoustics
#1 BASIC STRUCTURE – SINGLE MODULE CONTROL PULPIT
•The enclosure to be constructed in unitized form and shall be fully welded, utilizing tubular steel products.
•Unit will have crane lifting lugs fully welded at reinforced vertical members.
•The door openings to have a vertical subframe of 4" tubular steel to prevent deflection, displacement, and twisting of the steel doors and frames.
•Wall system to be utilized within the 4" tubular steel panel superstructure to be CID wall panel.
•Exterior wall panels to be carbon steel plate with continuous weld seams and VOC compliant alkyd industrial enamel finish.
•The 4" wall system to incorporate mineral fiber acoustical insulating blanket.
•This insulation will serve as a thermal barrier, dust barrier, and sound deadener.
•The interior porcelain enamel finish steel hard wall panels are extremely rugged, nonchalking, corrosion resistant, and maintenance free.
•The unitized tubular steel framework is designed for and will accommodate recessed structural steel channels inside the lifting crown framework.
•A 10 gauge carbon steel load bearing roof shall be placed and fully seam welded (continuous) at panel junctures and at the structure periphery.
•The completed roof material system shall be fully load bearing to meet owner specification.
•The completed roof system is weather and water tight.
#3 FLOOR FRAMING, FINISHED FLOOR, DOORS, FRAMES, & ACOUSTICS
•Floor framing materials to consist of tubular steel perimeter base members and structural steel C-channels, located to support exterior undercover as well as the finished floor system.
•Steel C-channels are to be welded to the unit superstructure tubular steel base.
•Finished subfloor of the structure to be steel plate.
•Area between the interior and exterior floors to have mineral fiber insulating material, securely fastened to the understructure of the finished floor system.
•The fire resistant, mildew proof insulation is inert and will provide both sound and thermal protections.
•Exterior doors to be supplied with the enclosure at the entry locations.
•All surfaces receiving coating shall be properly prepared as per paint manufacturer's specifications prior to the application of the first prime coat.
•Paint color selection and accents to be as selected by the owner. Corporate colors and company logos may be provided at no additional charge.
•The CID state of the art liftable building shall be furnished with an integral electrical wiring system, including one 12 circuit, 125 amp rated distribution panel.
•The load center to accommodate duplex wall receptacles with GFI protection where required.
•Surface mount 2' x 4' fluorescent light fixtures will be provided.
•All wiring is to be installed as per NEC code and to be installed with recessed EMT metal conduit.
•Independent electrical inspection certificate may be provided if requested.
•Ceiling mounted dual head emergency light unit is included with lighted exit sign at the door(s).
ADDITIONAL OPTIONS INCLUDE:
•Walkways, stairs, platforms with support structures for elevated installation, and HVAC equipment.